If a firmware update fails eg. due to power loss during update, the firmware may become corrupted. If a device operates abnormally after a failed update, try to Factory Reset it. If abnormal operation persists after a Factory Reset, the device may be recoverable by using the Firmware Upgrade Utility to reinstall the firmware.

    1. Connect directly to the switch with an ethernet cable to PC/laptop.
    2. Navigate to Control Panel > Network and Internet > Network Connections
    3. Right-click on the network adapter used to connect to the switch and select “Properties”:Network Adapters - Control Panel
    4. Select “Internet Protocol Version 4 (TCP/IPv4)” and click “Properties”
      Ethernet Adapter Properties
    5. Select “Use the following IP address” and assign a static address in the range of 192.168.1.1 – 192.168.1.254, except 192.168.1.224, accept the default subnet mask of 255.255.255.0 and set the Default gateway to 192.168.1.224
      TCP/IP address properties
    6. Navigate to Control Panel > System & Security > Windows Defender Firewall and ensure that Windows Firewall is completely turned off
    7. Confirm TCP connectivity to the switch by opening a Command Prompt and issuing command ping 192.168.1.224
      Command Prompt - ping switch
    8. Use the latest version of the Firmware Upgrade Utility (3.6.10 as of ) available from https://www.draytek.com.au/support/downloads/
    9. Click OK at the firewall warning
      Firewall warning
    10. Enter the IP address of the switch, or click the ” . . . ” box to detect it on the network and select
      Firmware Upgrade Utility
      Select Device
    11. Click the “. . .” box to select the firmware file
      Select Firmware file
      Select firmware file 2
    12. Enter the admin password (default password is admin if you haven’t changed it) in the password field, and click the “Send” button:
      Enter password

    13. Progress bar will appear as firmware is uploaded and installed to the switch. Do not power off, reset or reboot the switch.  This will take several minutes to complete:

      Send firmware

    14. Pop-up will appear.  Do not power off, reset or reboot the switch.  This will take several minutes to complete:
      Pop-up a
    15. Once complete, you will see a final pop-up:
      Pop-up b

The switch should now be reachable on its web interface at http://192.168.1.224 (Default username/password admin/admin)

VigorSwitch G1282 login page

See also:
Upload Firmware to the Router via TFTP – https://www.draytek.com/support/knowledge-base/5222

Posted by Shaun, 05/09/2024